Does a water heater need a temperature and pressure relief valve?
Yes — every water heater must have a temperature-and-pressure relief valve (or separate temperature and pressure valves) set to open by 210°F and 150 psi (IRC P2804).
The IRC requires every water heater to be protected by a temperature-and-pressure (T&P) relief valve, or by separate temperature and pressure relief valves. The temperature element must open at no more than 210°F (99°C), and the pressure relief at no more than 150 psi (IRC P2804.3 and P2804.4).
The valve's discharge pipe must run full-size to a safe spot, terminate near the floor or outdoors, and cannot have a shutoff valve, threaded end, or trap that could block flow (IRC P2804.6.1).
These devices prevent the tank from over-pressurizing. The discharge line must never be capped or plugged.
Verified against
Related answers
- When does a house need a carbon monoxide alarm? — IRC §R315.2
- How much combustion air does a gas furnace or water heater need indoors? — IRC §G2407.5
- Does a water heater or furnace in a garage have to be raised off the floor? — IRC §M1307.3
- Can HVAC return air be pulled from a bathroom, kitchen, or garage? — IRC §M1602.2
- When does a water heater need a drain pan, and what size is the drain? — IRC §P2801.6
- Does every plumbing fixture need a P-trap? — IRC §P3201.6
- Do outdoor hose bibbs need a backflow preventer? — IRC §P2902.4.3
- What is the minimum shower size allowed by code? — IRC §P2708.1
- Do I need a permit to replace a water heater? — IRC §R105.1
Have a question about your own project?
Adopted edition and local amendments vary by city and county. Get answers with code references to verify against your local code.
Ask Donnie →General information based on the International Residential Code (a model code). This is AI assistance to verify — not legal advice. Confirm the adopted edition and any local amendments with your local building department (AHJ) and a licensed professional before you build.