When does a house need a carbon monoxide alarm?
CO alarms are required in dwellings that contain a fuel-fired appliance or have an attached garage (IRC R315.2, 2015 edition).
The IRC requires carbon monoxide alarms in dwelling units that contain a fuel-burning appliance (gas, oil, wood, etc.) or that have an attached garage, since both are potential sources of carbon monoxide. (This is Section R315.2 in the 2015 IRC; earlier editions place the rule under R315.1.)
All-electric homes with no fuel-fired appliances and no attached garage are generally not required to have CO alarms under the base code, although local amendments can be stricter.
Verified against
Related answers
- Where are smoke alarms required in a house? — IRC §R314.3
- Do smoke alarms have to be interconnected? — IRC §R314.4
- Where should carbon monoxide alarms be installed? — IRC §R315.3
- What is the fire separation between units in a duplex? — IRC §R302.3
- How much combustion air does a gas furnace or water heater need indoors? — IRC §G2407.5
- Does a water heater or furnace in a garage have to be raised off the floor? — IRC §M1307.3
- Does a water heater need a temperature and pressure relief valve? — IRC §P2804
- Can HVAC return air be pulled from a bathroom, kitchen, or garage? — IRC §M1602.2
Have a question about your own project?
Adopted edition and local amendments vary by city and county. Get answers with code references to verify against your local code.
Ask Donnie →General information based on the International Residential Code (a model code). This is AI assistance to verify — not legal advice. Confirm the adopted edition and any local amendments with your local building department (AHJ) and a licensed professional before you build.