Do outdoor hose bibbs need a backflow preventer?
Yes — sillcocks, hose bibbs, and wall hydrants must have a vacuum breaker to prevent backflow into the potable supply (IRC P2902.4.3).
The IRC requires every outdoor hose connection — sillcocks, hose bibbs, and wall hydrants — to be protected against backflow by a vacuum breaker. This stops contaminated water (from a hose left in a pool, bucket, or sprayer) from being siphoned back into the drinking-water supply.
Acceptable protection includes an atmospheric-type or pressure-type vacuum breaker, a pressure vacuum breaker assembly, or a permanently attached hose-connection vacuum breaker. Many modern frost-proof sillcocks have an integral breaker built in.
On an existing outdoor faucet, a simple screw-on hose-bibb vacuum breaker satisfies the requirement.