What is the minimum size for a roof ridge board?

IRC §R802.3model code

A ridge board must be at least 1 inch nominal thickness and no less in depth than the cut end of the rafter (IRC R802.3).

Where rafters meet at a ridge, they must be placed directly opposite each other and nailed to a ridge board. The ridge board supports and aligns the rafter ends in a conventionally framed roof.

The IRC requires the ridge board to be at least 1 inch nominal in thickness and not less in depth than the cut (plumb) end of the rafter, so the full bearing of the rafter is supported.

A non-structural ridge board is different from a structural ridge beam; a ridge beam is sized by engineering when it carries roof loads instead of relying on ties.