How much attic/ceiling insulation does the energy code require by climate zone?
Ceilings need R-30 in zone 1, R-38 in zones 2-3, and R-49 in zones 4-8 (IRC Table N1102.1.1).
The IRC energy-efficiency table sets minimum ceiling (attic) insulation by climate zone: R-30 in zone 1, R-38 in climate zones 2 and 3, and R-49 in zones 4 through 8. These are the prescriptive minimums for the building thermal envelope.
To actually achieve the rated R-value over the exterior walls, the insulation has to keep its full thickness above the wall top plate, which is why raised-heel (energy) trusses are commonly used at the eaves so the attic insulation isn't compressed.
This is Table N1102.1.1 in the 2012 IRC (renumbered Table N1102.1.2 in 2015); the R-30/38/49 values are the same in both editions. Your local jurisdiction may amend the adopted edition, so confirm which one applies.
Verified against
Related answers
- What is the minimum size for a roof ridge board? — IRC §R802.3
- When are rafter ties required, and how far apart can they be? — IRC §R802.3.1
- How much attic ventilation do I need? — IRC §R806.2
- What size does an attic access opening need to be? — IRC §R807.1
- What blower-door air leakage rate does code require for a new house? — IRC §N1102.4.1.2
- How much insulation do HVAC ducts in the attic need? — IRC §N1103.2.1
Have a question about your own project?
Adopted edition and local amendments vary by city and county. Get answers with code references to verify against your local code.
Ask Donnie →General information based on the International Residential Code (a model code). This is AI assistance to verify — not legal advice. Confirm the adopted edition and any local amendments with your local building department (AHJ) and a licensed professional before you build.