How much attic ventilation do I need?
Net free ventilating area must be at least 1/150 of the vented attic area (IRC R806.2).
The IRC requires the total net free ventilating area to be no less than 1/150 of the area of the space being ventilated. 'Net free area' is the actual open area of the vent, not its overall size, since screens and louvers reduce airflow.
This baseline 1/150 ratio can be reduced to 1/300 only when specific balancing or vapor-retarder conditions are met. Ventilation openings must be protected against the entry of rain, snow, and pests.