Do I have to use tamper-resistant outlets in a house?
Yes — 15- and 20-amp, 125-volt receptacles in dwelling units must be listed tamper-resistant type (IRC E4002.14).
In the areas where receptacles are required in a dwelling, 15- and 20-amp, 125-volt non-locking receptacles must be the listed tamper-resistant type. These have internal shutters that block foreign objects, which reduces the risk of a child being shocked.
There are a few exceptions — for example, receptacles located more than 5.5 feet above the floor, and receptacles that are part of a light fixture or appliance, are not required to be tamper-resistant.
Tamper-resistant receptacles are marked 'TR' on the face.
Verified against
Related answers
- How far apart do wall outlets have to be (the 6/12 foot rule)? — IRC §E3901.2
- How many outlets do I need on a kitchen counter and how far apart? — IRC §E3901.4
- Where does the outlet have to be in a bathroom? — IRC §E3901.6
- Which outlets in a house have to be GFCI protected? — IRC §E3902
- Where is AFCI (arc-fault) protection required in a house? — IRC §E3902.16
- How much clearance is required in front of an electrical panel? — IRC §E3405.2
Have a question about your own project?
Adopted edition and local amendments vary by city and county. Get answers with code references to verify against your local code.
Ask Donnie →General information based on the International Residential Code (a model code). This is AI assistance to verify — not legal advice. Confirm the adopted edition and any local amendments with your local building department (AHJ) and a licensed professional before you build.