How do I attach a deck ledger to the house?
Use ½-inch lag screws or through-bolts spaced per Table R507.2 into a solid band joist — never nails — with proper flashing (IRC R507.2).
A deck ledger carrying up to 50 psf must be fastened to a 2-inch nominal band joist with ½-inch lag screws or bolts and washers, spaced according to Table R507.2 (spacing varies with the joist span). The ledger itself should be at least a 2x8 of pressure-preservative-treated lumber.
Nails and ordinary deck screws are not permitted for the ledger-to-band-joist connection. Fasteners must be hot-dipped galvanized or stainless steel, and lag screw tips must fully extend past the inside face of the band joist.
Flash the ledger per Section R703.4 so water cannot reach the house rim. The ledger also may not be attached over exterior veneer such as brick or stucco.
Verified against
Related answers
- What is the deck lateral load connection requirement? — IRC §R507.2.3
- How much force does a deck guardrail or handrail have to resist? — IRC §R301.5
- At what height does a deck, porch, or stair need a guard? — IRC §R312.1.1
- How far apart can balusters be on a railing? — IRC §R312.1.3
- How much bearing do floor joists and girders need at the ends? — IRC §R502.6
- How much can you notch or bore a floor joist? — IRC §R502.8.1
- What is the anchor bolt spacing for a sill plate on a foundation? — IRC §R403.1.6
- How big does a crawl space access opening have to be? — IRC §R408.4
Need this scoped to your jurisdiction?
Adopted edition and local amendments vary by city and county. Ask Donnie checks your jurisdiction and cites the exact adopted section.
Ask Donnie →General information based on the International Residential Code (a model code). This is AI assistance to verify — not legal advice. Confirm the adopted edition and any local amendments with your local building department (AHJ) and a licensed professional before you build.